Whatsapp:0086 15076729161        Email: sales@aistar.cn.com
Your position: Home > Fuel & Clean Energy Dispenser > Fuel Dispenser

AISTAR-2 fuel dispenser

Single and double nozzle fuel dispenser
Item Code: AI1-4021
    Please select the information you wantX
+
-
Units
  • Description

Basal Date
2 × Product (Suction type)
2 × Motor, Single phase, 220V, 50Hz, 0.75Kw
2 × Tatsuno type gear pump
2 × Tatsuno type flow meter
2 × OPW type nozzle 11A, 3/4'', outlet: 13/16''
2 × Black rubber hose, length: 4 m with couplings
2 × Solenoid valve
2 × Break away valve, 3/4''
2 × Hose swivels
1 × Eletronic controller
2 × Present keyboard, white color
4 × Display board × 330,886, white
All painting body
Power supply: 220V 50Hz
Package: Standard Export Carton

FUEL DISPENSERS

TECHNICAL SPECIFICATIONS FOR FUEL DISPENSERS

1.0 TYPES OF FUEL DISPENSERS

1) Single Product, Single Nozzle, Standard Duty Fuel Dispensers (40 l/min)
2) Single Product, Single Nozzle, Heavy Duty Fuel Dispensers (65 l/min)
3) Two Product, Dual Nozzle, Standard Duty Fuel Dispensers (40 l/min)
4) Two Product, Dual Nozzle, Heavy Duty Fuel Dispensers (65 l/min)

2.0 GENERAL
  Parameter Value/Description
01 Fuel to be pumped Standard Duty -> Motor Gasoline, Auto Diesel & Kerosene
Heavy Duty -> Auto Diesel
02 Flow Rate Standard Duty -> 40 l/min
Heavy Duty -> 65 l/min
03 Accuracy/Maximum permissible error ± 0.25%
04 Power Supply 230V ± 6% Single phase, 50 Hz ± 1%.
05 Ambient Temperature
06 Relative Humidity 60-95%(None condensing)
07 Location Outdoor, hazardous/classified area
08 Noise Level Shall not exceed 75 dB at 1 meter
09 Vibration Within the limits specified in ISO 2372or equivalent
10 Protection Overload and short circuit protection to be provided as standard. Further the electronic hardware shall be protected against lightning induced surge.
3.0 MAIN DISPLAY
  Parameter Value/Description
01 Type LCD Display with back light for clear visibility at day/night
02 Character/Digit height(minimum) Volume/Amount : 1”
Unit price : ¾”
03 Display Cover Plain Glass
04 Units Volume : l (Litre)
Price : Rs. (Rupees)
05 Unit Price Minimum 5 Digits including 2 decimals.(Rs. 0.01 – 999.99)
06 Volume Preset Standard Duty ->0.5 – 999 Litres.
Heavy Duty -> 1 – 999 Litres.
07 Price Preset (Cash) Minimum 5 Digits (Rs. 50 – 99999)
08 Volume Display Minimum 6 Digits including 3 decimals. 0.000 – 999.999 Litres
09 Price/Cash Display Minimum 8 digits including 2 decimal Rupees (Rs.) 0.00 – 999999.99
4.0 KEYPAD WITH LCD DISPLAY

Keypad and back lit LCD display shall be IP 65 rated. Amount, Volume preset data shall be entered using keypad. Unit price and pump settings shall be edited from keypad with password and key protection.

5.0 FLOW METER/METERING UNIT.
  Parameter Value/Description
01 Type Positive Displacement piston type volumetric meter with stainless steel seamless liners and corrosion resistant materials.
02 Least Measurement 0.01 l
03 Pulser 100 pulses/litre (minimum)
04 Calibration Adjustment Mechanical/Electronic
05 Flow Control Valve Solenoid operated two stage or better flow control valve certified by UL,BASSEFA or FM.

Tamper proof sealing arrangement shall be incorporated for metering unit. Accuracy shall be maintained at all possible flow rates.

6.0 NON RESETTABLE CUMULATIVE TOTALIZER FOR VOLUME
6.1 ELECTRONIC TOTALIZER

1. Electronic totalizer with 09 digits including 03 decimals which should reset after 999999.999 or with more digits with similar reset pattern.
2. Whatever the quantity of fuel which passes through the flow meter shall be recorded in the totalizer. This shall include the volume of fuel pumped at the beginning of each delivery which is not displayed in the main display.(i.e. 60 ml in most of dispenser makes)
3. Electronic totalizer record shall not be affected (i.e. erased or changed) due to power surge, power failure, removal/interchanging of any hardware component.
4. Internal computation of volumes should be performed to an accuracy of at least 4 decimal places. (5 or more decimals preferable)

6.2 MECHANICAL/ELECTRO-MECHANICAL TOTALIZER

Mechanical /electro-mechanical totalizer should be available with 07 Digits.

7.0 PUMPING UNIT AND COMPONENTS

1. Gear/Vane type pump with bypass valve
2. Working Pressure < 0.3 MPa
3. Inlet Vacuum >= 50.0 KPa
4. Strainer – The pumping unit shall be equipped with a suction side strainer having reinforced, corrosion resistant screen for use with Motor Gasoline/Auto Diesel. It shall be easily removable for cleaning or replacement.
5. Air Separator and release – The pumping unit shall be equipped with as air eliminator unit and venting shall unit and venting shall comply with the requirement of ANSI/UL 87 or equivalent.
6. Pressure Relief Devices – Pumping unit shall be equipped with a manual or self-adjusting bypass valve capable of bypassing the entire output of the pump and fuel expansion pressure relief valve.
7. Check Valve – The pumps shall be provided with check valve on the suction side to keep the discharge lines full of fuel.
8. Material of Construction – The material used in the construction of external parts of the pumping unit shall not contain more than 7.5 % Magnesium according to EN13463-1 clause 8.2 – Non electrical equipment for use in potentially explosive atmosphere part 1-Basic Methods & Requirements.

8.0 MOTHERBOARD & OTHER ELECTRONIC HARDWARE

The Design/Construction of electronic hardware shall be of surface mounting technology. Designs which contain EEPROMs mounted on IC bases are not accepted. Tamper proof sealing method shall be provided for the motherboard.
Serial Number or Identification No. of the Mother Board shall be readable in the Main Display or Keypad Display. (or etched on PCB) . Serial Number printed on sticker paper will not be accepted.

9.0 ELECTRIC MOTOR
  Parameter Value/Description
01 Capacity(minimum) 0.75 Hp/0.5 kW(Standard Duty)
1 Hp/.75 kW (Heavy Duty)
02 Duty Cycle Continuous
03 Hazardous area Certification Zone 1, Gas Group II A according to IEC
04 Enclosure Exd II A T 3
05 Cooling method IC 411 (According to IEC 34-6)
06 Degree of protection IP 55
07 Insulation class F
08 Balancing Motor should be dynamically balanced
09 Standards & Codes Applicable The motor shall be manufactured according to ANSI, NFPA, NEC, API, IEEE, NEMA, BS, IEC, VDE or any other equivalent International standards.
10.0 DISPENSER CABINET
  Parameter Value/Description
01 Material Galvanized steel EN10142 with powder coatings(Electrostatic coating
02 Panel Covers Shall be Epoxy Coated Steel
03 Panel Locks Durable Panel key Locks shall be provided
04 Approximate Dimensions 1000 mm x 500 mm x 2000 mm
05 Color Colour of the Panel covers should be white. Otherwise CPC product color code will be noticed at the time of ordering.
11.0 HOSE, NOZZLE AND CONFIGURATION
    Standard Duty Heavy Duty
01 Nozzle Automatic Shut off Nozzle (¾” BSPT female thread preferred) Spout Diameter 16 mm Automatic Shut off Nozzle (1” BSPT female thread preferred)Spout Diameter 24 mm
02 Hose
1. Diameter
2. Wall Thickness
3. Minimum Length
4. Couplings

19 mm (¾”)
Minimum 6.0 mm
4m
¾” BSPT (preferred) chrome plated brass swivel couplings, male thread at one end and female thread at the other end.

25 mm (1”)
Minimum 6.0 mm
4m
1” BSPT (preferred) chrome plated brass swivel couplings, male thread at one end and female thread at the other end.

    Single Product Double Product
01 No. of Hoses 1 2
02 No. of Pump Units 1 2
03 No. of Metering Units 1 2
04 No. of Main Displays 2 4
05 No. of Mechanical Totalizer 1 2

 Hose with swivel couplings and nozzle valve shall comply with the requirements of ANSI/UL 87 & bear the listing marks of Underwriters Laboratory (UL).
 Intake flexible pipe should be at the bottom of the Dispensing Pumps.
 The hose shall be oil resistant with static wire and hose guard.
 Flow indicator (Sight Glass) shall be fixed to the delivery line at a clearly visible location
 A breakaway coupling shall be fixed in the delivery hose.

12.0 FUEL DISPENSER MARKING

The name plate (marking plate) shall be in accordance with typical 94/9/EC marking & shall bear the markings according to EN 13617-1 safety requirements for construction & performance of metering pumps, dispensers & remote pumping unit.
Other essential markings shall include Model, Serial Number, Year of Manufacture & homologation number (Approval number from competent metrology authority)

13.0 HAZARDOUS/CLASSIFIED AREA CLASSIFICATION

The fuel dispenser shall be certified to Ex 11 2G as per ATEX.
All electrical & non-electrical equipment & components shall be designed & constructed according to good engineering practice & in conformity with the required categories for Group II equipment of the ATEX 94/9/EC directive to ensure avoidance of any ignition sources as stipulated in EN 1127-1.
Undesirable electrical discharge shall be avoided by earthing & interconnecting all the metallic components of electrical & non electrical equipment.

14.0 IN-BUILT PRINTER

Printer should be available for issuing receipts to customers with dealer identification, date, and time, per litre price, volume of sale, amount of sale, vehicle Number and dispenser identification.

15.0 ACCESS TO USE SMART/LOYALTY CARDS AND INTEGRATION WITH POINT OF SALE (POS)

An Industry Standard Communication interface shall be provided to interface the fuel dispenser with POS & smart payment systems.

16.0 OPERATIONAL REQUIREMENTS AND OTHER FEATURES

 Battery backup shall be provided to display the last delivery data for a minimum of 5 min during power failure
 The interrupted delivery could be resumed only if the power is restored within 3 secons.
 Motor should automatically shut off after 0 to 30 sec (user adjustable) after the product delivery is stopped. (Default 10 seconds).
 Motor should be automatically shut off when the Nozzle is replaced on the Nozzle boot.
 Presets shall be provided for volume basis as well as Cash (Value) basis
 Memory recalls of previous sales value or similar figures shall be retrievable only on side Display.(not on main display)
 A clear distinct beep at Zero Reset shall be provided.
 The product delivery shall start with 2 seconds delay after the nozzle is lifted from nozzle boot
 When the underground tank goes empty the meter should not run.

17.0 REFERENCE STANDARDS

Design, construction and performance of the Fuel dispensing pumps shall be in compliance with the requirements of the International standards listed below.

1. The Fuel Dispensing Pumps Model/s offered shall hold a pattern approval as per the requirements of International Organization of Legal Metrology (O1ML) standard R 118 :2000 “Testing Procedures and Test Report format for Pattern Examination of fuel dispensers for Motor Vehicles and constituent Element” & OIML R 117 :1995 “Measuring System for Liquids other thanwater”
A certified copy of O1ML Pattern Approval or Pattern Approval issued by the authorised Local Metrological Department for Measurement Apparatus in the manufacturing country accepted by the OIML and test reports shall be submitted along with the bid.
Further, pattern approval for the fuel dispensing pumps model/s offered obtained from Measurement Units, Standards and Services Department of Sri Lanka at No. 101, Park Road, Colombo 05, Sri Lanka,Email: metroload@sltnet.lk .T/P Nos. 0094-11-2583261//2597757/2587190/2588914 Fax No. 0094-11-2597756shall be submitted.

2. Design and Safety requirements (Fire and Casualty Hazard) and material specification shall be as per the requirements of Underwriters Laboratories (UL) Standard for safety ANSI/UL 87 “Power operated Dispensing devices for Petroleum Product”. or DIN EN 13617 – 1 : 2004 Petrol Filling Stations – Part I : Safety Requirements for Construction & Performance of Metering umps, dispensers & remote pumping units. If the design & safety requirement of the Fuel Dispensing Pump is covered by any other local standard applicable in the manufacturing country, the Supplier shall declare the same & furnish references.

3. Certificates issued by BASEEFA, UL, FM, CSA, or any other International Recognized Independent testing authority authorized to issue IEC EX certification for the electric motor and other accessories such as pulse generator, nozzle switch transmitter, Electric shut of valve, junction boxes for installation in Zone 1, Gas Group 11A classified area, as per IEC.

4. ISO 9001 – 2000 for quality system for Design, Development, Manufacture &Supply of Fuel Dispensing Pumps.

5. IEC 61000-4-11 (1994-06) Electromagnetic compatibility (EMC) – Part 4, Testing and Measuring Techniques – Section 11, Voltage dips, short interruptions and voltage variations immunity tests.
6. IEC 61000-4-4 (1999 – 01) Electromagnetic Compatibility (EMC) – Part 4 Testing and Measurement Techniques – Section 4 Electrical fast transient/burst immunity test.
7. IEC 61000-4-2, Electromagnetic compatibility (EMC) – Part 4, Testing and Measurement Techniques – Electrostatic discharge immunity test.
8. IEC 61000-4.3, Electromagnetic compatibility (EMC) – Part 4, Testing and Measuring Techniques – Radiated, Radio-Frequency Electromagnetic field immunity test.
9. The Fuel Dispensing Pump Hardware (i.e. electronic register and peripheral devices) shall be protected against lightning induced transients as per requirements IEEE C62.41.

18.0 TYPICAL INSTALLATION DATA AT CPC OUTLET
  Parameter Value
01 Inlet Pipe Size 38 mm
02 Length of Suction Pipe
Horizontal
Vertical
20m(approximate)
3.5m(approximate)
03 No of Bends 4(approximate)
03 No of Tank-top non return valve 1
Customer Reviews
Average rating:

5(based on 922 reviews)

Share your thoughts with other customers